Two different jobs behind one spec sheet
A wedge window and a transmission witness sample are often compared because both are round optics with a thickness callout, but they answer different questions. The wedge window is an active beam-steering element: Esco’s Precision Wedge Windows, S1-UV Grade Fused Silica, for example, carry a deliberate 30-minute wedge so direct back reflections do not return down the incoming path. A transmission witness sample is a quality reference tied to a melt lot, not a steering component.
That distinction matters when you read a spec such as 1.400–1.599. In the Esco catalog, that range is the refractive-index band for the Witness Sample, Transmission, 1.400–1.599, which is supplied in materials from CaF2 up through S-BAL35. It is not a wedge angle, a deviation figure, or a property of the S1-UV wedge window.
Wedge window vs parallel window: what changes in the beam path
The practical difference is what happens to light that would otherwise reflect straight back toward the source.
- Parallel window: The two surfaces are parallel, so a direct back reflection can travel back along the incoming path. Esco describes its precision wedge windows as similar to precision flat windows except for the deliberate wedge.
- Wedge window: The 30-minute wedge between surfaces means the back reflection leaves at an angle instead of retracing the input path. Esco lists interferometer flats, laser windows, beamsplitter substrates, and parallel plates among the intended uses.
- What the supplied record does not give: The catalog states the wedge as 30 minutes but does not supply a separate beam-deviation value in degrees or milliradians. Treat the wedge angle as the design input and calculate or measure deviation for your own layout rather than assuming a number from the listing.
S1-UV wedge window evidence that shapes the choice
- Precision Wedge Windows, S1-UV Grade Fused Silica: Precision laser quality round wedge windows are ideal for applications where direct back reflections would be a problem; these elements are similar to precision flat windows but have a deliberate wedge of 30 minutes. This is the core functional difference from a parallel window and the reason to choose a wedge at all.

Precision Wedge Windows, S1-UV Grade Fused Silica - Precision Wedge Windows, S1-UV Grade Fused Silica: Optical flat wedges range from λ/4 (0.25 waves) to λ/10 (0.10 waves) flatness. Flatness is a separate selection axis from wedge angle; the listing offers both grades, so match flatness to the wavefront tolerance your setup needs.
- Precision Wedge Windows, S1-UV Grade Fused Silica: Available variants pair diameter and thickness with either 0.25 - λ/4 or 0.1 - λ/10 surface flatness. Diameter, thickness, and flatness are chosen together; the record does not confirm additional diameters beyond the listed variants.
Where the 1.400–1.599 transmission witness fits
The Witness Sample, Transmission, 1.400–1.599 is a melt-lot-controlled reference polished on both sides to 60-40 scratch-dig, with each side flat to better than 1 wave at 633 nm over 80% clear aperture and parallelism better than 1 arc minute. Its diameter is 25.40 mm and thickness 1.50 mm. The refractive index values listed are representative of n_d at 587 nm, and individual melt data is available on request.
Those numbers describe a witness sample’s optical quality and material identity. They do not describe beam steering. If your question is “how much will my beam deviate,” the witness sample is the wrong component to read for an answer, even though its 1.400–1.599 band overlaps the index territory of common optical glasses.
Transmission witness sample evidence and its limits
- Witness Sample, Transmission, 1.400-1.599: Witness sample diameter is 25.40 mm and the thickness is 1.50 mm. These are the supplied dimensions; they are fixed for this witness sample and are not a wedge-window size option.

Witness Sample, Transmission, 1.400-1.599 - Witness Sample, Transmission, 1.400-1.599: All of our witness samples are melt lot controlled and individual melt data is available on request. Melt traceability is the witness sample’s purpose; it supports material verification rather than beam deviation.
- Witness Sample, Transmission, 1.400-1.599: The refractive index values listed are representative of n_d at 587 nm. The 1.400–1.599 label is an index reference point, not a wedge or deviation specification.
A practical way to compare the two before ordering
Use the decision sequence below to keep the two product families from being substituted for each other.
- Start with the beam problem: If back reflection is the issue, the wedge window is the relevant family; if you need a traceable transmission reference for a melt lot, the witness sample is.
- Read the wedge angle, not the index band: The S1-UV wedge record states a 30-minute wedge. The 1.400–1.599 figure belongs to the witness sample’s index labeling and should not be read as a steering angle.
- Choose flatness and size from the variant list: The wedge window variants pair diameter and thickness with λ/4 or λ/10 flatness. The witness sample is a single 25.40 mm × 1.50 mm format.
- Confirm what the listing does not state: Neither supplied record gives a beam-deviation value, a transmission curve, or a coating specification. Where those matter, ask Esco directly rather than inferring them.
The honest tradeoff
A wedge window adds a controlled angular offset to the transmitted beam and moves the back reflection away from the source, which is why Esco positions it for laser windows and interferometer flats. A parallel window keeps the beam path simpler, but it does not solve a direct back-reflection problem on its own. The witness sample does neither job: it documents material and polish quality for a melt lot.
If your layout needs a specific deviation figure, the supplied catalog does not provide one for the S1-UV wedge window. Use the 30-minute wedge as the starting design fact and verify deviation against your own source wavelength and geometry. If you need a traceable transmission reference, the 1.400–1.599 witness sample is the right record to read, but its dimensions and index values are not interchangeable with wedge-window selection.