What a Reflection Witness Sample Does in Coating QA
A reflection witness sample is a small, polished substrate that goes through the same coating run as your production optics. After coating, you measure its reflectance to verify that the coating process met your specifications—without risking damage to the actual coated part. Esco Optics offers reflection witness samples precision polished on one side to a scratch-dig of 60-40, with the second side ground. This design gives you a reliable reference surface for reflection measurements.
Key Specifications for Coating Verification
- Witness Sample, Reflection, 1.400-1.899: Flatness is < 1 wave @ 633nm at 80% CA. Parallelism < 1 arc min. Flatness and parallelism ensure that the witness sample itself does not introduce measurement error. A flat surface gives you a true reflection signal from the coating, not from sample deformation.

Witness Sample, Reflection, 1.400-1.899 - Witness Sample, Reflection, 1.400-1.899: Precision polished on one side to a scratch-dig of 60-40. The second side is ground. The polished side is the measurement surface. The ground side prevents unwanted back-surface reflections that could corrupt the reflectance reading.
- Witness Sample, Reflection, 1.400-1.899: All witness samples are melt lot controlled and individual melt data is available on request. Melt lot control lets you trace the substrate's refractive index and homogeneity back to the original glass melt. This traceability is essential for repeatable coating runs and audit records.
Practical Sequence for Using a Reflection Witness Sample
The steps below assume you have a coated witness sample and a calibrated reflectometer or spectrophotometer. Always follow your own facility's safety and handling protocols.
- Inspect the witness sample before coating: Check the polished surface for visible defects using a bright light. The scratch-dig spec of 60-40 means minor scratches and digs are allowed, but any damage larger than that can affect the measurement. Confirm the diameter (25.40 mm) and thickness (1.50 mm) fit your sample holder.
- Run the witness sample through the coating process: Place the witness sample in the coating chamber alongside your production optics. The ground side should face away from the coating source unless your process requires a different orientation. The sample must experience the same deposition conditions as the production parts.
- Measure reflectance after coating: Use a spectrophotometer or reflectometer to measure the polished side. The ground side will scatter light, so it will not contribute a specular reflection. Compare the measured reflectance curve to your coating design target. The flatness (< 1 wave @ 633nm) ensures the sample does not distort the measurement.
- Record melt lot data for traceability: Request individual melt data from Esco Optics for the witness sample's refractive index. Record the lot number with your coating run data. This documentation supports quality audits and troubleshooting if the coating performance drifts over time.
Choosing the Right Refractive Index Variant
The reflection witness sample is available in several refractive index materials, including S-BSL7 (1.517), UV Fused Silica (1.458), S-FPL53 (1.438), SF-11 (1.785), and SF-57 (1.846). Choose the material that matches the substrate of your production optics. A mismatch in refractive index can affect the coating design, especially for antireflection or beamsplitter coatings that rely on precise layer indices. If your production part is made from a glass not listed, contact Esco Optics to discuss custom options.
Limitations and Practical Tradeoffs
A reflection witness sample only measures reflectance, not transmittance or absorption. For a complete coating characterization, you may need a transmission witness sample or a separate absorption measurement. The witness sample's flatness and parallelism are specified at 80% clear aperture; measurements near the edge may be less reliable. Also, the scratch-dig spec of 60-40 means the polished surface is not perfect—small cosmetic defects are acceptable and should not affect most reflectance measurements, but inspect the sample before use if your measurement requires an extremely clean surface.