Start with the focal line, not the lens
A cylindrical lens behaves differently from a spherical lens: the curved surface is shaped like a cylinder, so performance is characterized by a focal line that lies parallel to the cylindrical axis. That single fact drives almost every setup decision. Before you order, decide where that line needs to fall, how long it should be, and which axis of your system it must align with.
Esco's G1 Commercial Grade Fused Quartz cylinder lenses are plano-convex elements made in standard sizes. The catalog lists options by diameter and focal length, so the practical setup question is usually which combination places the focal line where your detector, slit, or workpiece expects it.
Orienting the lens so the focal line lands correctly
The cylindrical axis, not the mechanical edge of the mount, defines the line direction. Use these checkpoints in order.
- Identify the cylindrical axis: The curved surface is cylindrical, and the focal line runs parallel to that cylinder axis. Mark the axis direction on your mount or bench before inserting the lens.
- Align the axis to the feature you are imaging or illuminating: For slit imaging in spectroscopic instrumentation, the line should follow the slit. For laser line generation used in measurement or alignment, the line should follow the measurement direction.
- Set the working distance from the focal length: Choose the focal length that places the focal line at your intended plane. The catalog offers multiple focal length options at each diameter; the right one depends on your layout, not on a universal rule.
- Confirm the plano side and convex side suit your mount: These are plano-convex elements. The supplied record does not specify a preferred facing direction for every application, so verify orientation against your own optical design rather than assuming a default.
- Check the line before committing to a permanent mount: Inspect the focal line position and orientation at low power first. Adjust rotation about the optical axis until the line matches the target feature.
Matching diameter and focal length to the job
The available variants pair a diameter with a focal length. Larger diameters collect more light and suit broader beams; shorter focal lengths produce a tighter focal line closer to the lens, while longer focal lengths place the line farther away with a gentler convergence.
Because the record supplies only diameter and focal length as option types, treat other parameters such as coating, edge treatment, and mounting hardware as items to confirm with Esco before ordering. Do not assume a coating or mount is included.
What the G1 fused quartz record confirms
- Cylindrical Lenses, G1 Fused Quartz, Commercial Grade: Plano-convex G1 Commercial Grade Fused Quartz cylinder lenses, pitch polished for precision surface quality and accuracy. Pitch polishing is the supplied quality statement for these standard elements; it tells you the surface is finished to a commercial specification rather than a laser-grade one.

Cylindrical Lenses, G1 Fused Quartz, Commercial Grade - Cylindrical Lenses, G1 Fused Quartz, Commercial Grade: Performance is characterized by a focal line parallel to the cylindrical axis. This is the orientation rule for every setup: the line direction follows the cylinder axis, not the lens edge.
- Cylindrical Lenses, G1 Fused Quartz, Commercial Grade: Standard variants are listed by diameter and focal length, with multiple focal length choices at each diameter. Use the diameter to match beam size and the focal length to set working distance; both are selectable at order time.
Where commercial grade cylindrical lenses fit
The supplied record names several application areas. These are the jobs the lens is described for, not a guarantee of performance in every system.
- Imaging linear arrays in optical data storage and retrieval: The focal line can be aligned to a linear array so the array is imaged along one axis.
- Imaging slits in spectroscopic instrumentation: A cylindrical lens can match the line to a slit geometry, which is one of the named uses in the record.
- Generating a narrow line of light from a laser: Cylindrical lenses are frequently used with lasers to produce a narrow line for measurement or alignment.
- Scanning techniques: The record lists scanning processes among the application areas, though it does not specify scan speeds or control requirements.
Fused quartz vs glass cylindrical lenses: what the record supports
The record identifies the substrate as G1 fused quartz and the grade as commercial. It does not provide a side-by-side optical comparison with N-BK7 or other glasses, so the honest comparison is about what is confirmed versus what you must verify.
- Fused quartz (this product): Confirmed: G1 fused quartz substrate, commercial grade, pitch polished, plano-convex cylindrical form. Not confirmed in the supplied record: transmission curve, damage threshold, or index homogeneity.
- Other optical glasses: The record does not supply comparison data for other glasses. If your application depends on a specific transmission band or thermal behavior, request that data from Esco rather than inferring it.
- Custom elements: Esco states it can manufacture custom elements, including negative cylindrical lenses and lenses made of other optical materials. That is the route when a standard positive cylinder does not fit.
Line generator setup: practical checkpoints
For a laser line generator, the lens turns a beam into a line rather than a point. The record supports the concept and the orientation rule; it does not supply divergence angles or recommended distances, so set those from your own layout.
- Choose focal length for line placement: The focal line sits at the focal length from the lens. Pick the variant whose focal length matches where the line must appear.
- Rotate to set line direction: Rotating the lens about the optical axis rotates the focal line. Use this to align the line with the measurement or alignment axis.
- Keep the beam within the clear aperture: The record does not state clear aperture values. Confirm the usable aperture for your chosen diameter with Esco before relying on the full diameter.
- Verify at low power first: The record does not supply a damage threshold. Do not assume laser power handling; confirm suitability with Esco for your wavelength and power.
When a standard commercial grade lens is not enough
Commercial grade and pitch polishing describe the standard product. If your application requires a documented surface figure, a specific coating, or a substrate other than G1 fused quartz, the supplied record does not confirm those attributes for this item. In that case, contact Esco directly at 800-922-3726 or by email; the record states the company can manufacture custom elements including negative cylindrical lenses and lenses in other optical materials.
For a standard positive cylinder in a linear-array, slit-imaging, or laser-line application, the catalog variants give you a straightforward starting point: pick the diameter that captures your beam and the focal length that places the line where you need it.